<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>Iranian Research Organization for Science and Technology (IROST)</PublisherName>
				<JournalTitle>Hydrogen, Fuel Cell &amp; Energy Storage</JournalTitle>
				<Issn>2980-8537</Issn>
				<Volume>13</Volume>
				<Issue>3</Issue>
				<PubDate PubStatus="epublish">
					<Year>2026</Year>
					<Month>10</Month>
					<Day>27</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Hydrogen Production Potential of a System Powered by Geothermal Energy and Thermoelectric Generators</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>187</FirstPage>
			<LastPage>194</LastPage>
			<ELocationID EIdType="pii">1487</ELocationID>
			
<ELocationID EIdType="doi">10.22104/hfe.2024.7170.1325</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>Ghanim Kadhim Naser</FirstName>
					<LastName>Al-Shammari</LastName>
<Affiliation>Mechanical Engineering Department, Engineering Faculty, Urmia University, Urmia, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Majid</FirstName>
					<LastName>Abbasalizadeh</LastName>
<Affiliation>Mechanical Engineering Department, Engineering Faculty, Urmia University, Urmia, Iran</Affiliation>
<Identifier Source="ORCID">0000-0002-5269-0037</Identifier>

</Author>
<Author>
					<FirstName>Iraj</FirstName>
					<LastName>Mirzaee</LastName>
<Affiliation>Mechanical Engineering Department, Engineering Faculty, Urmia University, Urmia, Iran</Affiliation>
<Identifier Source="ORCID">0000-0002-3523-5251</Identifier>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2026</Year>
					<Month>07</Month>
					<Day>03</Day>
				</PubDate>
			</History>
		    <Abstract>This study presents a thermodynamic analysis of a power, refrigeration, and hydrogen production cycle utilizing geothermal energy in a binary flash cycle. The system combines a basic vapor-compression refrigeration cycle with a binary flash cycle and a PEM electrolyzer, with geothermal energy serving as the driving force. A thorough thermodynamic simulation was carried out using EES software, followed by a parametric study of the proposed cycle to evaluate its performance under varying input parameters. The results indicate that TEG 2 and the compressor exhibit the highest exergy destruction rates, as revealed by the exergy degradation rate analysis. Furthermore, increasing the temperature of the first flash tank leads to higher hydrogen and power production rates. In contrast, raising the temperature of the second flash tank results in decreased energy and exergy efficiency, as well as lower power and hydrogen generation rates. Additionally, an increase in the geothermal mass flow rate leads to a reduction in both power and hydrogen production. Finally, it is observed that a larger temperature difference causes a decrease in the hydrogen generation rate.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Binary flash cycle</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Geothermal energy</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Thermodynamic analysis</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Hydrogen production</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://hfe.irost.ir/article_1487_6d3a1e06d6a06349436bc054313b648c.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Iranian Research Organization for Science and Technology (IROST)</PublisherName>
				<JournalTitle>Hydrogen, Fuel Cell &amp; Energy Storage</JournalTitle>
				<Issn>2980-8537</Issn>
				<Volume>13</Volume>
				<Issue>3</Issue>
				<PubDate PubStatus="epublish">
					<Year>2026</Year>
					<Month>10</Month>
					<Day>01</Day>
				</PubDate>
			</Journal>
<ArticleTitle>4E Analysis of a Geothermal-Based Multigeneration System</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>195</FirstPage>
			<LastPage>208</LastPage>
			<ELocationID EIdType="pii">1614</ELocationID>
			
<ELocationID EIdType="doi">10.22104/hfe.2025.7613.1359</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>Hanaa</FirstName>
					<LastName>Kadhim Kareem Alsabahi</LastName>
<Affiliation>Department of Mechanical Engineering, Urmia University, Urmia, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Majid</FirstName>
					<LastName>Abbasalizadeh</LastName>
<Affiliation>Department of Mechanical Engineering, Urmia University, Urmia, Iran</Affiliation>
<Identifier Source="ORCID">0000-0002-5269-0037</Identifier>

</Author>
<Author>
					<FirstName>Ata</FirstName>
					<LastName>Chitsaz</LastName>
<Affiliation>Department of Mechanical Engineering, Urmia University, Urmia, Iran</Affiliation>
<Identifier Source="ORCID">0000-0002-4061-001X</Identifier>

</Author>
<Author>
					<FirstName>Morteza</FirstName>
					<LastName>Khalilian</LastName>
<Affiliation>Department of Mechanical Engineering, Urmia University, Urmia, Iran</Affiliation>
<Identifier Source="ORCID">0009-0003-1907-3461</Identifier>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2026</Year>
					<Month>06</Month>
					<Day>29</Day>
				</PubDate>
			</History>
		    <Abstract>This study aims to assess a new geothermal multisource energy system upon a comprehensive 4E framework of the Energy, Exergy, Economic, and Environmental aspects. The system integrates numerous technologies for energy conversion and use, which includes an Organic Rankine Cycle (ORC) coupled with a Thermoelectric Generator (TEG), a Single-Effect Absorption Chiller (SEAC), a Proton Exchange Membrane (PEM). A distinct benefit of the system is its use of a TEG instead of the usual condenser, allowing waste heat to be converted into extra electricity via the Seebeck effect, thus enhancing the efficiency of energy conversion without using extra power. The multigeneration system is designed to produce electricity, heating, cooling, hydrogen and freshwater which makes it perfect for regions endowed with geothermal resources and various energy demands. The simulation results demonstrating a comprehensive thermodynamic simulation indicate that the system has 66.42% energy efficiency and 77.12% exergy efficiency. According to the exergoeconomic analysis, the overall capital and the maintenance cost expended is mostly driven by the turbines and geothermal unit, although optimization possibilities can be made within heat exchangers and condensers. The optimization of the heat recovery and design of cultural thermal solutions can not only reduce energy losses but also increase performance and benefit the overall costs, ensuring thermal efficiency. In general, activity environment index of the system 0.03206 corresponds to minimal direct ecological disturbance, and its exergy sustainability coefficient is 0.0711, which points out the possibility of further enhancement of sustainability. This geothermal setup is poised excellently as an efficient, sustainable and multipurpose energy solution as per results.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">4E analysis</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Geothermal energy</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">polygeneration systems</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">TEG</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">environmental study</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://hfe.irost.ir/article_1614_e9fd7c2c6623306db59b6aef5c0d5cac.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Iranian Research Organization for Science and Technology (IROST)</PublisherName>
				<JournalTitle>Hydrogen, Fuel Cell &amp; Energy Storage</JournalTitle>
				<Issn>2980-8537</Issn>
				<Volume>13</Volume>
				<Issue>3</Issue>
				<PubDate PubStatus="epublish">
					<Year>2026</Year>
					<Month>09</Month>
					<Day>01</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Process Modeling and Optimization of Coal Gasification for Enhanced Hydrogen and Syngas Yield in Sponge Iron Production</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>209</FirstPage>
			<LastPage>222</LastPage>
			<ELocationID EIdType="pii">1623</ELocationID>
			
<ELocationID EIdType="doi">10.22104/hfe.2025.7606.1358</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>Mohsen</FirstName>
					<LastName>Bahoosh</LastName>
<Affiliation>Department of Chemical Technologies, Iranian Research Organization for Science and Technology (IROST), Tehran, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Eslam</FirstName>
					<LastName>Kashi</LastName>
<Affiliation>Department of Chemical Technologies, Iranian Research Organization for Science and Technology (IROST), Tehran, Iran</Affiliation>
<Identifier Source="ORCID">0000-0001-5296-0415</Identifier>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2026</Year>
					<Month>07</Month>
					<Day>17</Day>
				</PubDate>
			</History>
		    <Abstract>Due to the irregular availability of natural gas, coal has been proposed as an alternative source for the production of synthesis gas in steel plants. This study simulated a coal gasification unit aimed at producing synthesis gas. The developed model was initially validated using available reference data, confirming its reliability and accuracy. Using Tabas coal as feedstock, the gasification process was simulated in Aspen Plus software using an entrained-flow gasifier. Sensitivity analysis was conducted on the type of coal, as well as the water-to-coal and oxygen-to-coal ratios, to identify key factors affecting the gasification process. The key results show that approximately 22 tons per hour of Tabas coal are required to produce 77000 Nm3/h of syngas, sufficient to support the production of 110 tons per hour of sponge iron. Process water consumption is around 0.3 times the coal input, with a cooling and quenching water-to-coal ratio of approximately 1.7, much of which is reused. Significantly, additional water is not required for the water-gas shift reaction due to syngas quenching within the gasifier. The study confirmed that the type of coal and the ratios of water-to-coal and oxygen-to-coal are critical parameters, with high-quality Tabas coal demanding lower amounts of oxygen and water for syngas production compared to lower-grade coals. This research serves as a valuable guide for improving the efficiency and productivity of coal gasification units in the steel industry. Overall, the findings indicate that using coal for synthesis gas production has great potential in meeting energy demands and enhancing productivity in the steel industry.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Coal gasification</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Syngas</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Tabas coal</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Steel</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Aspen Plus</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://hfe.irost.ir/article_1623_fc528592c3858f90196fbfacc814f235.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Iranian Research Organization for Science and Technology (IROST)</PublisherName>
				<JournalTitle>Hydrogen, Fuel Cell &amp; Energy Storage</JournalTitle>
				<Issn>2980-8537</Issn>
				<Volume>13</Volume>
				<Issue>3</Issue>
				<PubDate PubStatus="epublish">
					<Year>2026</Year>
					<Month>10</Month>
					<Day>30</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Molecular Simulation Study of CO2 Removal from H2 Stream by SIFSIX-3-Cu Adsorbent</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>223</FirstPage>
			<LastPage>234</LastPage>
			<ELocationID EIdType="pii">1714</ELocationID>
			
<ELocationID EIdType="doi">10.22104/hfe.2026.7794.1376</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>Rouhollah</FirstName>
					<LastName>Rahimnahal</LastName>
<Affiliation>Chemical Engineering Department, Ilam University, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Behrouz</FirstName>
					<LastName>Bayati</LastName>
<Affiliation>Chemical Engineering Department, Ilam University, Iran</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2026</Year>
					<Month>07</Month>
					<Day>09</Day>
				</PubDate>
			</History>
		    <Abstract>The gradual depletion of fossil fuel reserves has renewed interest in hydrogen (H2) as a durable and sustainable energy carrier. However, its successful application on an industrial scale hinges on removing trace contaminants particularly carbon dioxide (CO2) from mixed gas streams. In this study, the separation of CO2 from CO2/H2 mixtures was investigated using the metal organic framework SIFSIX 3 Cu and Grand Canonical Monte Carlo (GCMC) simulations across a wide range of temperatures and pressures. Two gas compositions (molar ratios CO2/H2 of 0.90/0.10 and 0.79/0.21) were examined between 298 K and 370 K. In every case, CO2 uptake was markedly higher than that of H2, and the adsorption of both gases decreased with increasing temperature. The Langmuir isotherm model provided an excellent fit to the observed data, indicating monolayer adsorption behavior. The isosteric heats of adsorption were calculated to be about 54kJ mol-1 for CO2 and roughly 2kJ mol-1 for H2, reflecting the stronger electrostatic attraction between CO2 molecules and the SiF62- sites in the framework. Spatial density distribution analysis revealed that CO2 molecules preferentially occupy regions near the SiF62- units, whereas H2 molecules are mainly located around pyrazine rings. Overall, these findings highlight the pronounced CO2 selectivity of SIFSIX 3 Cu even at low concentrations and underline its potential for hydrogen purification in industrial gas separation processes.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Metal-Organic Frameworks</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Grand Canonical Monte Carlo</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Hydrogen purification</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Isosteric heat of adsorption</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://hfe.irost.ir/article_1714_798ed7d4ee7138d49b8828958048130a.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Iranian Research Organization for Science and Technology (IROST)</PublisherName>
				<JournalTitle>Hydrogen, Fuel Cell &amp; Energy Storage</JournalTitle>
				<Issn>2980-8537</Issn>
				<Volume>13</Volume>
				<Issue>3</Issue>
				<PubDate PubStatus="epublish">
					<Year>2026</Year>
					<Month>09</Month>
					<Day>30</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Sustainable Energy Production: Thermodynamic Evaluation of Geothermal-Based Multigeneration System</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>235</FirstPage>
			<LastPage>246</LastPage>
			<ELocationID EIdType="pii">1753</ELocationID>
			
<ELocationID EIdType="doi">10.22104/hfe.2025.7590.1357</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>Arkan</FirstName>
					<LastName>Jabbar Farhan Farhan</LastName>
<Affiliation>Faculty of Mechanical Engineering, University of Urmia, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Majid</FirstName>
					<LastName>Abbasalizadeh</LastName>
<Affiliation>Faculty of Mechanical Engineering, University of Urmia, Iran</Affiliation>
<Identifier Source="ORCID">0000-0002-5269-0037</Identifier>

</Author>
<Author>
					<FirstName>Shahram</FirstName>
					<LastName>Khalilarya</LastName>
<Affiliation>Faculty of Mechanical Engineering, University of Urmia, Iran</Affiliation>
<Identifier Source="ORCID">0000-0002-6434-852X</Identifier>

</Author>
<Author>
					<FirstName>Samad</FirstName>
					<LastName>Jafarmadar</LastName>
<Affiliation>Faculty of Mechanical Engineering, University of Urmia, Iran</Affiliation>
<Identifier Source="ORCID">0000-0001-5029-8456</Identifier>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2026</Year>
					<Month>07</Month>
					<Day>17</Day>
				</PubDate>
			</History>
		    <Abstract>This study presents a financial and thermal analysis of a novel geothermal multigeneration system capable of producing electricity, cooling, fresh water, and hydrogen. The system uniquely integrates several innovative technologies as follows: Integration of Organic Rankine cycle (ORC), and Kalina cycle for efficient geothermal power generation; transcritical CO2 cooling combined with single-effect absorption refrigeration to enable both cooling and energy generation for multi-purpose operation; regasification of Liquefied Natural Gas (LNG) as an energy reservoir of accumulating the cold energy; Proton Exchange Membrane (PEM) electrolyzer and Reverse Osmosis (RO) unit, operating the produced power for hydrogen and fresh water production, respectively. The integration of these cycles and technologies is being pioneered for the first time, a representing novel towards optimized energy and water generation from geothermal sources. The system produces a gross electrical power output of 5,962.4 kW, with an overall exergy efficiency of 32.04%, and an exergy efficiency of 11.65% specifically for electricity production. The study of exergy destruction shows turbines, compressors and heat exchangers as the primary inefficiency sources, providing space for their future optimization. The system’s performance higher geothermal source temperatures; increasing the source temperature from 380 K to 415 K results in significant gains in both power and freshwater production, highlighting the importance of high-quality geothermal resources. The system’s economic performance is confirmed by a total production cost of $6559 per GJ. The potential of geothermal-powered multigeneration systems in optimizing the resource use, delivering sustainable energy, and water solutions is shown in this research.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Renewable energy integration</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Exergy destruction analysis</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Sustainable hydrogen generation</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">geothermal</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://hfe.irost.ir/article_1753_a63fc8c5d915e1f1a40f40e6c7499863.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Iranian Research Organization for Science and Technology (IROST)</PublisherName>
				<JournalTitle>Hydrogen, Fuel Cell &amp; Energy Storage</JournalTitle>
				<Issn>2980-8537</Issn>
				<Volume>13</Volume>
				<Issue>3</Issue>
				<PubDate PubStatus="epublish">
					<Year>2026</Year>
					<Month>11</Month>
					<Day>03</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Impact of Solar Radiation on Hybrid Nanofluid Dynamics in Rotating Microchannels</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>247</FirstPage>
			<LastPage>266</LastPage>
			<ELocationID EIdType="pii">1754</ELocationID>
			
<ELocationID EIdType="doi">10.22104/hfe.2026.7647.1365</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>Ali</FirstName>
					<LastName>Ahmadi Azar</LastName>
<Affiliation>Department of Mechanical Engineering, NT.C., Islamic Azad University, Tehran, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Zahra</FirstName>
					<LastName>Poolaei Moziraji</LastName>
<Affiliation>Department of Mechanical Engineering, NT.C., Islamic Azad University, Tehran, Iran</Affiliation>
<Identifier Source="ORCID">0000-0002-0151-0040</Identifier>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2026</Year>
					<Month>07</Month>
					<Day>18</Day>
				</PubDate>
			</History>
		    <Abstract>This study examines solar radiation effects on hybrid nanofluid behavior in a rotating microchannel. Governing nonlinear partial differential equations were transformed into dimensionless ordinary differential equations using similarity variables and solved analytically via the Hybrid Analytical and Numerical Method (HAN-method). Results indicate that increasing the rotation parameter reduces average fluid velocity in the x- and y-directions while enhancing z-direction velocity. Greater fluid suction at the upper wall elevates the surface friction coefficient and Nusselt number at the lower wall. Higher Reynolds numbers decrease temperature while increasing z-axis velocity, with corresponding increases in Nusselt number and surface friction coefficient at the bottom wall. Augmented solar radiation and temperature ratio parameters increase both Nusselt number (lower wall) and average fluid temperature. This research provides quantitative analytical solutions and introduces a novel validation methodology, representing a significant advancement over prior approaches.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Radiative solar energy</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Microchannel</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Hybrid nanofluid</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Three-dimensional flow</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Thermal radiation</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://hfe.irost.ir/article_1754_231141b34c82aa95e48810a9d1b33a79.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Iranian Research Organization for Science and Technology (IROST)</PublisherName>
				<JournalTitle>Hydrogen, Fuel Cell &amp; Energy Storage</JournalTitle>
				<Issn>2980-8537</Issn>
				<Volume>13</Volume>
				<Issue>3</Issue>
				<PubDate PubStatus="epublish">
					<Year>2026</Year>
					<Month>11</Month>
					<Day>02</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Evaluation of Bipolar Plate Bonding Adhesives with the Aim of Increasing PEM Fuel Cell Power Density</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>267</FirstPage>
			<LastPage>278</LastPage>
			<ELocationID EIdType="pii">1755</ELocationID>
			
<ELocationID EIdType="doi">10.22104/hfe.2026.7891.1382</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>Mohammad Mahdi</FirstName>
					<LastName>Barzegari</LastName>
<Affiliation>Northern Research Center for Science and Technology, Malek-Ashtar University of Technology, Iran</Affiliation>
<Identifier Source="ORCID">0000-0001-8429-5536</Identifier>

</Author>
<Author>
					<FirstName>Mojtaba</FirstName>
					<LastName>Ghadimi</LastName>
<Affiliation>Northern Research Center for Science and Technology, Malek-Ashtar University of Technology, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Seyed Mostafa</FirstName>
					<LastName>Seyyedi</LastName>
<Affiliation>Department of Mechanical Engineering, Technical and Vocational University (TVU), Tehran, Iran</Affiliation>
<Identifier Source="ORCID">0009-0000-7911-1907</Identifier>

</Author>
<Author>
					<FirstName>Hamid</FirstName>
					<LastName>Hassanzadeh Afrouzi</LastName>
<Affiliation>Department of Mechanical Engineering, Technical and Vocational University (TVU), Tehran, Iran</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2026</Year>
					<Month>07</Month>
					<Day>31</Day>
				</PubDate>
			</History>
		    <Abstract>One of the strategies to increase the power density of fuel cells is reducing the thickness of composite bipolar plates. However, considering the brittle nature of these plates, a reduction in thickness may result in fracture under applied loading. The use of adhesives for sealing, instead of elastomeric gaskets on the cooling side of bipolar plates, enables bonding of the anode and cathode plates together, thereby improving mechanical strength. Consequently, applying adhesives can significantly enhance the power density of the fuel cell. In this study, the performance of structural (epoxy–phenolic) and non-structural (fluorinated vinyl ester) adhesives was evaluated under fuel cell operating conditions. Essential properties such as adhesion strength, effective sealing, ease of preparation and application, thermal stability, and chemical resistance in the acidic fuel cell environment were investigated. The results revealed that epoxy–phenolic adhesives, due to their high shear strength, negligible weight loss, dense cross-linked structure, and the presence of phenolic rings, are more suitable for structural applications. In contrast, fluorinated vinyl ester adhesives exhibited zero weight loss under the same conditions and excellent chemical resistance, but lower mechanical strength. Specifically, EP-Ph10 exhibited a lap shear strength of 10.2 MPa, while VES-PFO5 showed 8.4 MPa. Chemical resistance tests indicated &lt;0.5% weight loss for EP-P, EP-Ph5, EP-Ph10, VES, and VES-PFO5, whereas EP-D showed approximately 2.0% weight loss in H2SO4 and ∼3.0% in HF after 30 days.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">fuel cell</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Structural epoxy-phenolic adhesives</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Fluorinated vinyl ester</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Chemical resistance</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">thermal stability</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://hfe.irost.ir/article_1755_d8d31bd778da8bdd536187c36e48892b.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Iranian Research Organization for Science and Technology (IROST)</PublisherName>
				<JournalTitle>Hydrogen, Fuel Cell &amp; Energy Storage</JournalTitle>
				<Issn>2980-8537</Issn>
				<Volume>13</Volume>
				<Issue>3</Issue>
				<PubDate PubStatus="epublish">
					<Year>2026</Year>
					<Month>09</Month>
					<Day>30</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Robust Multi-Criteria Optimization of a Residential Power–Heat–Hydrogen Polygeneration System: Integrating HOMER Scenarios with Monte Carlo–Fuzzy TOPSIS</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>279</FirstPage>
			<LastPage>296</LastPage>
			<ELocationID EIdType="pii">1756</ELocationID>
			
<ELocationID EIdType="doi">10.22104/hfe.2026.8194.1398</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>Alireza</FirstName>
					<LastName>Solat</LastName>
<Affiliation>Department of Electrical Engineering, Sav.C., Islamic Azad University, Saveh, Iran</Affiliation>
<Identifier Source="ORCID">0000-0001-8012-0851</Identifier>

</Author>
<Author>
					<FirstName>Mehdi</FirstName>
					<LastName>Jahangiri</LastName>
<Affiliation>Energy and Environment Research Center, ShK.C., Islamic Azad University, Sharekord, Iran.</Affiliation>
<Identifier Source="ORCID">0000-0001-6803-8804</Identifier>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2026</Year>
					<Month>07</Month>
					<Day>08</Day>
				</PubDate>
			</History>
		    <Abstract>This study aims to identify the optimal configuration of a polygeneration (power-heat-hydrogen) system at the residential scale through a case study of a 90 m2 residential apartment in Tehran, Iran. The novelty of this study lies in integrating scenario simulation in HOMER with the Fuzzy TOPSIS multi-criteria decision-making framework and evaluating the robustness of the decision under uncertainty using Monte Carlo-TOPSIS. Four scenarios -- PV-Grid, Grid, PV-Wind-Grid, and Wind-Grid -- were evaluated based on the criteria of the levelized cost of electricity (COE), the levelized cost of hydrogen (COH), \ce{CO2} emissions, and the share of renewable energy in electricity and heating. Fuzzy TOPSIS results indicated that Scenario 1 (PV-Grid) is the best option under both weighting policies, with a Closeness Coefficient (CC) of 0.99 in the Cost-priority policy and 0.98 in the Climate-priority policy. Scenario 3 (PV-Wind-Grid) ranked second, with CC values of 0.74 and 0.79. Scenarios 4 and 2 performed the worst, with CC values of approximately 0.11-0.13 and 0.02-0.06, respectively. Monte Carlo analysis reported a rank-1 probability equal to 0.99 for Scenario 1 and 0.01 for Scenario 3. Furthermore, the stability of Scenario 1 was confirmed with a very small interquartile range (IQR) (maximum 0.00475 at ±50%) and a mean CC of 0.984738. The findings are applicable to system designers, researchers, and policymakers in the building sector for resilient decision-making.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Multi-criteria decision-making</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Uncertainty analysis</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Ranking stability</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Sensitivity analysis</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Weighting policy</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://hfe.irost.ir/article_1756_cefab442b1728a7c1b49c63f1a55781c.pdf</ArchiveCopySource>
</Article>
</ArticleSet>
